BFKNC - ENAMEL,HEAT RESISTANT,BLACK, TT-E-496BTYPE1

  • MSDS: BFKNC
  • Manufacturer: TRIAD PAINT AND CHEMICAL CORP
  • Product Name: ENAMEL,HEAT RESISTANT,BLACK, TT-E-496BTYPE1
  • National Stock Number: 8010-00-664-3643
Product Identification

Product ID:ENAMEL,HEAT RESISTANT,BLACK, TT-E-496BTYPE1
MSDS Date:01/01/1985
FSC:8010
NIIN:00-664-3643
MSDS Number: BFKNC

Responsible Party
TRIAD PAINT AND CHEMICAL CORP.
810 EVERGREEN AVE
BROOKLYN, NY 11207-1140
US

Cage: 33151

Contractor
TRIAD PAINT AND CHEMICAL CORP
BROOKLYN, NY 11207-1140 US

Cage: 33151

Ingredients

SOLVENTS

Fraction By Weight: 50%

ACGIH TLV: 200 PPM

Hazards

Effects of Overexposure:SKIN,EYE
IRRITANT,ANESTHESIA,HEADACHE,DIZZINESS,NAUSEA

First Aid

First Aid:SKIN CONTACT-WASH WITH SOAP AND WATER.EYE CONTACT-FLUSH WITH
PLENTY OF WATER.INHALATION-REMOVE TO FRESH AIR AND RESTORE
BREATHING IF REQUIRED

Fire Fighting

Flash Point:111F,44C TCC
Lower Limits:1.0
Upper Limits:6.0
Extinguishing Media:FOAM,CO*2,STEAM,WATER FOG,DRY CHEMICAL
Fire Fighting Procedures:EXCLUDE AIR,DO NOT USE WATER,CONSULT FIRE
MARSHALL
Unusual Fire/Explosion Hazard:VAPOR FORMS EXPLOSIVE MIXTURE WITH AIR
BETWEE VAPOR AND LOWER EXPLOSION LIMITS

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES,VENTILATE AREA.

Handling

Handling and Storage Precautions:AVOID IGNITION SOURCES.AVOID SPLASH
FILLING.PROVIDE ADEQUATE VENTILATION.AVOID EXCESSIVE HEAT

Exposure Controls

Respiratory Protection:ORGANIC CANNISTER MASK OR AIR PACK
Ventilation:MECHANICAL WITH APPROVED CLASSD EXPLOSION PROOF
MOTOR/SWITCH
Protective Gloves:NOT REQUIRED
Eye Protection:GOGGLES/SAFETY GLASSES
Supplemental Safety and Health

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:323F,162C
Vapor Pres:1
Vapor Density:5.0
Spec Gravity:0.77
Evaporation Rate & Reference:< BUTYL ACETATE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIGHT COLORED LIQUID,HYDROCARBON ODOR.
Percent Volatiles by Volume:56

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:CO,CO*2 WHEN COMBUSTED

Disposal

Waste Disposal Methods:EVAPORATION OR FLUSH WITH WATER IN WELL
VENTILATED AREA.USE OIL SEWER IF AVAILABLE OR REMOVE TO CONTAINER

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.